No end preparation. No threading equipment. High-strength lock-shear bolts create a self-indicating, friction-mechanical connection on standard deformed bar, in under two minutes.
Bar Range
End Prep
Install
Verify
Bolted Couplers provide the simplest splice solution, enabling fast, secure connections without threading, cutting, or grouting.
Both rebar ends- unmodified -are inserted into the split coupler sleeve from each side.
Bars are aligned centrally within the sleeve so both ends meet approximately at mid-length.
Lock-shear bolts are tightened progressively with a standard torque wrench until the heads shear off.
Inspect that all bolt heads have sheared- this confirms correct torque. Document and photograph for records.
| Size ID (mm) | Thread Pitch (mm) | Size OD (mm) | Length (mm) | Material |
|---|---|---|---|---|
| 16 | 20 × 2.5 | 28 | 40 | EN8D |
| 20 | 24 × 3 | 32 | 48 | EN8D |
| 25 | 29 × 3 | 40 | 60 | EN8D |
| 32 | 35 × 3 | 50 | 72 | EN8D |
| 40 | 45 × 4 | 63 | 90 | EN8D |
Industries We Serve